Skip to main content

Table 3 Effect of particle distance on CCC results

From: Colocalization by cross-correlation, a new method of colocalization suited for super-resolution microscopy

True distance (µm)

µ (µm)

σ (µm)

Confidence

R2

PCC

0

0 (0)

0.20 (< 0.01)

0.99 (< 0.01)

0.84 (0.01)

0.79 (< 0.01)

0.3

0.02 (0.05)

0.27 (0.02)

0.98 (< 0.01)

0.85 (0.04)

0.22 (0.03)

0.45

0.34 (0.03)

0.21 (0.02)

0.96 (< 0.01)

0.81 (0.06)

0.06 (0.01)

0.6

0.49 (0.01)

0.23 (0.01)

0.94 (< 0.01)

0.72 (0.13)

0.02 (< 0.01)

1.13

1.06 (0.02)

0.24 (0.02)

0.81 (0.01)

0.54 (0.11)

0 (< 0.01)

2.26

2.24 (0.02)

0.32 (0.07)

0.55 (0.01)

0.33 (0.08)

0 (< 0.01)

  1. Deconvolved SD-40 PSFs collected with a 40x/1.3 objective were used to generate input images for CCC with 50 spatially correlated pairings at various correlation distances. Results from the CCC plugin and Persons R value (PCC) for each distance are shown. All values are shown as Mean (SD) for n = 10 repeats